Assembly
Refer to the Assembly Instructions
for the installation.
Electrical installation
Warning! Only a qualified
person must do the electrical
installation.
The manufacturer is not
responsible if you do not follow
the safety precautions from the
Safety chapters.
This appliance is supplied without a main
plug and a main cable.
To access the electrical connections unscrew
the 2 T20 screws on the rear panel top and
take the panel out.
Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also
refer to the table:
Total power (W) Section of the cable
(mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).
Product description
General overview
1
2 3 4
5
6
7
1
2
3
4
1
Control panel
2
Temperature indicator
3
Knob for the temperature
4
Knob for the oven functions
5
Air vents for the cooling fan
6
Lamp
7
Shelf positions