Type of Gas
Burner
type
Injectors
1/100
mm
Nominal
Power
kW
Nominal
Flow g/h
Reduced
Power kW
by-pass
1/100 mm
G25 25 mbar Triple
Crown
147 4.0 - 1.2 56
G30/G31 30/30
mbar
Triple
Crown
98 4.0 291 1.2 56
Rating Plate
101-541-48
Made In Italy
© Inter IKEA Systems B.V. 1999
21552
PQM
PNC. 949738163 TYPE H3MF1TC0-G/VI
G25 25 mbar = 4 kW
G30/G31 30/30 mbar = 291 g/h
II2L3B/P (NL)
230 V
~
50 Hz
ZO 0694
The graphic above represents rating plate of
the appliance (without serial number which is
generated dynamically during the production
process), which is located at its underneath
surface of the casing.
Dear Customer, please apply here aside the
sticker you can find in the dedicate plastic bag
inserted inside the hob packaging. This will al-
low us to assist you better, by identifying pre-
cisely your hob, in case you will need in future
our assistance. Thank you for your help!
Installation
Warning! This appliance must be
installed, connected or repaired only by
a registered competent person to the relevant
gas standard. Use only original spare parts.
Manufacturer is not responsible for any injury
to persons and pets or damage to property
caused by failure to comply following require-
ments.
Caution! To proceed with the installation
refer to the assembly instructions.
Warning! Installation process must follow
the laws, ordinances, directives and
standards (electrical safety rules and
regulations, proper recycling in accordance
with the regulations, etc.) in force in the country
of use!
Ensure that the local distribution condi-
tions (nature of the gas and gas pressure)
and the adjustment of the appliance are com-
patible before proceeding with the installa-
tion.
The parameters of adjustment setting for
this appliance are stated on the rating
plate (refer to the Technical data chapter).
Warning! The appliance must be
earthed!
ENGLISH 8